Features

CIP-Adero® is an automated chamber cleaning solution designed to support the long-term performance of steam sterilisers used in CSSD environments. By removing deposits and restoring protective surfaces within the sterilisation chamber, it helps ensure consistent and reliable sterilisation outcomes for medical devices.

Developed specifically for use with MMM systems, CIP-Adero provides an efficient, automated approach to maintaining medical sterilisers, reducing manual intervention while supporting compliance and operational efficiency.

Alt Alt Alt Alt Alt Alt Alt Alt Alt Alt
Alt Alt Alt Alt Alt Alt Alt Alt Alt Alt
Product Code Product Description Pack Size Quote
10630780 CIP-Adero II 666-9612 for 1 machine, Selectomat PL ea
10630782 CIP-Adero II 666-9612 for 2 machines, Selectomat PL ea
10630783 CIP-Adero II 666-9612 for 3 machines, Selectomat PL ea
10630784 CIP-Adero II 666-9612 for 4 machines, Selectomat PL ea
10656269 CIP-Adero II 666-9612 for 1 machine, Selectomat SL ea

Managing Chamber Contamination (Rouging)

Over time, steam steriliser chambers can develop reddish-brown surface deposits, commonly referred to as rouging. These deposits form on stainless steel surfaces due to a combination of process conditions and environmental factors.

Potential causes may include:

  • Water or steam quality variations
  • Chemical residues introduced during processing
  • Incompatible cleaning chemicals
  • Secondary corrosion processes within the system

If left unmanaged, these deposits may impact confidence in sterilisation quality and the condition of the steriliser chamber.

A Smarter Solution for Steam Sterilisers

Automated Cleaning & Surface Restoration

CIP-Adero combines cleaning and repassivation to:

  • Remove corrosion deposits from chamber surfaces
  • Restore and reinforce the protective passive layer of stainless steel
  • Maintain hygienic conditions inside medical device steam sterilisers
  • Support consistent sterilisation performance over time

The process uses specially formulated cleaning agents that dissolve deposits while improving the corrosion resistance of the chamber material.

Designed for CSSD Efficiency

Fully Automated Process

  • Integrated system performs cleaning without manual intervention
  • No physical scrubbing required
  • No direct operator contact with chemicals
  • Cleaning cycles can be scheduled automatically

Consistent Routine Maintenance

  • Weekly routine cleaning cycles help maintain chamber condition
  • Intensive cleaning available for initial derouging
  • Automatic rinsing ensures complete removal of cleaning agents
  • Supports proactive maintenance of CSSD sterilisers

How CIP-Adero® Cleaning Works

The automated cleaning process includes:

  • Chamber conditioning and heating
  • Controlled dosing of cleaning solution
  • Circulation of cleaning solution through spray systems
  • Draining and rinsing using deionised water
  • Final rinse to ensure complete removal of residues

This sequence ensures effective cleaning while maintaining the integrity of the steriliser chamber.

Supporting Sustainability & Operational Efficiency

Environmentally Responsible Design

  • Cleaning agents based on biodegradable components
  • Reduced need for manual cleaning chemicals
  • Supports lower environmental impact over time

Reduced Labour & Downtime

  • Eliminates manual chamber cleaning processes
  • Reduces maintenance workload for CSSD teams
  • Minimises steriliser downtime due to cleaning
  • Improves overall operational efficiency

Flexible Integration with Steam Sterilisers

Designed for MMM Systems

  • Available as an option for new steam sterilisers
  • Can be retrofitted to existing MMM equipment
  • Configurable for single or multiple machines
  • Fully controlled through the steriliser system interface

Applications

CIP-Adero® supports the performance of:

  • Hospital CSSD departments
  • Centralised sterilisation units
  • Surgical centres and day hospitals
  • Facilities using high-capacity medical sterilisers

Part of a Complete CSSD Sterilisation Strategy

Maintaining your medical device steam sterilisers is essential for consistent performance.
CIP-Adero® complements your sterilisation equipment by supporting:

  • Chamber cleanliness and material integrity
  • Reliable sterilisation processes
  • Reduced maintenance effort
  • Long-term equipment performance

Applications

  • CSSD
  • Healthcare Facilities

Resources

  • video
  • Video
  • Video
  • Video
  • Brochure

Downloads

To access a copy of the eBook or product brochure, please complete and submit a copy of the Downloads form below.